DustVue 10 OS 1.03
9 change(s) - 07-05-2026
返回更新列表
DustVue 10 OS 1.03
更新: 07-05-2026
Change daily soiling ratio calculation method - average all "Last Soiling Ratio" calculations.
Preserve the soiling ratios calculated during the day so they are not lost due to a power loss.
Change the auto threshold to 40% (from 70%) of the measured clean cell irradiance during an offsets update.
Increase motor hold current.
When closing the cover, move it in further to address bounce/jam issue.
Don't do cover operations below -20°C.
Adjust heater turn on point.
Change bit 0 in System Status Code to stay set until another cover operation is attempted and rename it "Cover Operation Error".
Don't clear Sample Count register until midnight to ensure there is time to see last Sample Count increment.