CR6 OS 16.0.0
更新: 19-11-2026

  1. (New Feature) Added Support for CampbellON package manager.
  2. (New Feature) Add PakBus Identify Device Transaction.
  3. (New Feature) Add CSAT3C() and CSAT3CMonitor() CRBasic instructions.
  4. (New Feature) Added the "MQTTReconnectInterval" setting. Specifies the delay, in minutes, between attempts to reconnect to an MQTT broker following a failed connection attempt. The default value of 0 enables the datalogger's built-in reconnect backoff strategy.
  5. (New Feature) Added BasicJSON output format to Websocket API.
  6. (Major-Breaking) Updated the GeoJSON data format to always include the data table record number as the first value in each observation, providing consistency across Campbell Scientific dataloggers. The record number shifts all existing observation values by one position.
  7. (Major-Breaking) All recipes must contain "name" and "version" keys. "name" maps to a string value that is the user defined name of the recipe. "version" maps to a string value defining the recipe version, using semantic versioning (1.1.1). The empty string is not valid for either value.
  8. (Major-Breaking) Added idle connection timeouts to the HTTPS server and Telnet server to automatically close inactive connections and free up memory. Also improved HTTP/2 connection handling and fixed related WebSocket issues.
  9. (Major-Breaking) Added an idle connection timeout to TCP connections managed by the ModbusServer CRBasic instruction (ModbusTCP) when a constant integer representing server's listening TCP port is passed as the first argument. This timeout will close ModbusTCP connections after 10 minutes of inactivity to free up memory. ModbusTCP Clients communicating with the datalogger will need to be configured to open a new TCP connection if it has been closed. NOTE: This new timeout only affects the case where an integer constant representing the TCP port is passed to ModbusServer, leaving the ModbusServer instruction to manage TCP connections. If a variable containing a connection handle from TCPOpen is passed to ModbusServer (user is managing the TCP connection), this new idle timeout will not take affect and behavior will be the same as before this change.
  10. (Major) Improved FLL lock reliability by keeping the FLL enabled while the Minion is in sleep mode, eliminating the need to reacquire lock after each wake-up. This helps maintain a stable ComPort baud rate and resolves some cases of intermittent SDI-12 communication failures.
  11. (Major) Changed the default Cloud Config URL setting to point at CampbellON.
  12. (Major) Fixed an issue where data loggers running a Default.CRB program could enter a continuous reboot loop due to settings corruption. This occurred when the SerialOpen and SetSettings CRBasic instructions modified settings simultaneously. Updated SerialOpen to properly lock settings before making changes, preventing settings corruption and repeated reboots.
  13. (Major) Fixed an issue where ModbusClient() in Synchronous Retry mode within a SlowSequence could interfere with instructions in other CRBasic sequences.
  14. (Major) Fixed an issue where ModbusClient() in Asynchronous Retry mode could cause FTPClient in the main sequence to fail when running concurrently.
  15. (Major) Fixed an MQTTS issue where changing the MQTTEndpoint setting caused TLS connections to a different MQTT broker to fail until the data logger was rebooted. MQTT without TLS was not affected.
  16. (Major) Fixed an issue where SFTP connections failed when the SSH server negotiated an RSA host key. ECC host keys were unaffected.
  17. (Major) Reverted the SDI12Recorder CRBasic instruction break length from 14 ms to 12.5 ms. The SDI-12 1.4 standard requires a minimum break length of 12 ms. The break length was increased to 14 ms in the previous OS release to provide additional time for SDI-12 sensors to wake from a low-power state. However, some sensors did not reliably detect the longer break, resulting in communication issues. Restoring the break length to 12.5 ms improves compatibility with these sensors while maintaining compliance with the SDI-12 standard.
  18. (Major) Updated the MQTT reconnect backoff strategy to improve recovery from TLS failures by immediately retrying onboarding.
  19. (Major) Fixed a condition where data collection would work incorrectly for auto-allocated datatables with long data intervals.
  20. (Minor-Breaking) Modified the data logger HTTP(S) server to no longer automatically include the "Content-Encoding: gzip" header when serving files with a ".gz" extension. Previously, this header caused HTTP(S) clients, such as web browsers, to automatically decompress these files. With this change, compressed files are delivered in their original compressed format, allowing clients to manage decompression as needed. This change specifically addresses the unintended automatic decompression of ".tar.gz" archives created by the FileTar CRBasic instruction when downloaded through the datalogger HTTP(S) server.
  21. (Minor) Ensure the FTPClientActivePort setting is valid after updating from an OS before it was introduced.
  22. (Minor) Update qajson4c to version 1.1.1.
  23. (Minor) Fixed an issue where floating-point constants with whole-number values (such as 1.0 or 2.0) were incorrectly classified as integers, causing incorrect data to be sent by instructions such as ModbusClient.
  24. (Minor) Fixed an issue where CRBasic #If and #ElseIf statements could incorrectly evaluate expressions involving Double constants as false.
  25. (Minor) Fixed an issue where TableFile could stop creating new files after a data table was reset until the table reached its previous record count.